RT60 · 125 Hz to 4 kHz

Reverb time calculator

How long your room rings after a sound stops, band by band, and how much absorption it would take to tame it.

Your room

Units

Surfaces

Windows, rugs, panels, doors

Each item covers part of a surface; its area comes off that surface.

Target

ITU-R BS.1116-3 gives 0.17 s for a reference listening room of this volume. Type your own target, or .

Your reverb time

Sabine, 250 Hz–4 kHz
0.53 saverage of five octave bands
Eyring, 250 Hz–4 kHz
0.49 sshorter, as Eyring always is
Your target
0.17 sBS.1116-3 for this volume: 0.17 s
Room
34.3 m³1,210 ft³ · surfaces 65.0 m² (700 ft²)

Diffuse-field formulas: in a small room, treat these as rough estimates.

Reverb time by octave band, seconds

00.20.40.60.811252505001k2k4kHz

Bands, and what the target needs

By octave band
HzAbsorption, m² (ft²)Mean αSabine, sEyring, sExtra for the target, m², Sabine / EyringPanel area for the target
12516.66 (179.3)0.2560.330.2915.8 / 8.9none: the panel absorbs less than the surface it covers
2509.48 (102.0)0.1460.580.5423.0 / 16.137.7 m² (405 ft²) more than the bare walls
5008.43 (90.7)0.1300.650.6124.0 / 17.122.0 m² (237 ft²)
1k9.24 (99.5)0.1420.600.5523.2 / 16.320.7 m² (223 ft²)
2k12.12 (130.5)0.1860.460.4120.3 / 13.421.4 m² (230 ft²)
4k15.00 (161.5)0.2310.370.3217.5 / 10.619.4 m² (209 ft²)

Extra absorption is in m² of perfect absorber (metric sabins). The panel column turns the Sabine figure into an area of Glass-fibre board 51 mm (2 in), Owens Corning 703 on the walls, counting only what the panel adds over the surface it covers.

Surfaces counted

  • Walls 36.5 m² (393 ft²), 35.3 m² bare · Gypsum wallboard, ½ in on studs
  • Floor 14.3 m² (154 ft²) · Heavy carpet on felt backing
  • Ceiling 14.3 m² (154 ft²) · Gypsum wallboard, ½ in on studs
  • Window 1.2 m² (13 ft²) on the walls · Ordinary window glass

How the estimate works

Every surface soaks up part of the sound that hits it. Its absorption coefficient runs from 0 (reflects everything) to 1 (absorbs everything) and changes with frequency, so the calculator works band by band. Area times coefficient, added up over the room, gives the total absorption A, and Sabine’s formula turns it into a reverb time:

T = 0.161 · V / A  (Sabine)    T = 0.161 · V / (−S · ln(1 − ᾱ))  (Eyring)

V is the volume in m³, S the total surface area and ᾱ the average coefficient. Eyring always gives the shorter time; the gap grows as the room gets deader.

Treat the results as rough estimates. Both formulas assume a diffuse sound field, with sound arriving equally from every direction. Small rooms don’t behave like that, least of all in the bass, where room modes take over.

Pick materials from the published table, or choose custom coefficients and copy them from your panel’s data sheet. The target starts at ITU-R BS.1116-3’s value for a reference listening room; set your own for a live room or a vocal booth.

Sources

Absorption coefficients by octave band
Material1252505001k2k4kSource
Acoustic tile, rigid mount0.200.400.700.800.600.40Hall
Acoustic tile, suspended0.500.700.600.700.700.50Hall
Acoustical plaster0.100.200.500.600.700.70Hall
Ordinary plaster, on lath0.200.150.100.050.040.05Hall
Gypsum wallboard, ½ in on studs0.300.100.050.040.070.10Hall
Plywood sheet, ¼ in on studs0.600.300.100.100.100.10Hall
Concrete block, unpainted0.400.400.300.300.400.30Hall
Concrete block, painted0.100.050.060.070.100.10Hall
Concrete, poured0.010.010.020.020.020.03Hall
Brick0.030.030.030.040.050.07Hall
Vinyl tile on concrete0.020.030.030.030.030.02Hall
Heavy carpet on concrete0.020.060.150.400.600.60Hall
Heavy carpet on felt backing0.100.300.400.500.600.70Hall
Platform floor, wooden0.400.300.200.200.150.10Hall
Ordinary window glass0.300.200.200.100.070.04Hall
Heavy plate glass0.200.060.040.030.020.02Hall
Draperies, medium velour0.070.300.500.700.700.60Hall
Glass-fibre board 25 mm (1 in), Owens Corning 7030.050.260.630.880.970.94Owens Corning
Glass-fibre board 51 mm (2 in), Owens Corning 7030.150.711.141.161.021.00Owens Corning
Glass-fibre board 76 mm (3 in), Owens Corning 7030.341.091.251.151.051.00Owens Corning
Glass-fibre board 100 mm (4 in), Owens Corning 7030.561.261.221.111.070.96Owens Corning

Questions

Why does the bass stay long when I add panels?

Thin panels absorb little low down. In the Owens Corning data, 25 mm board has a coefficient of 0.05 at 125 Hz against 0.56 for 100 mm. Thicker panels, or panels spaced off the wall, reach lower.

Which result should I trust, Sabine or Eyring?

Neither exactly. They agree when a room is fairly live and drift apart as it gets deader, where Eyring is the better model. In a small room, use them to compare one treatment plan with another, and measure for real numbers.

What target should a home studio aim for?

The default is the value BS.1116-3 gives for reference listening rooms, which are built for critical listening tests; in a small room it is short. Use it as a goal for a mixing room, and set your own for a room you want to sound live.